LP-1000N Owner’s Manual Revisions Date Page No. Changes 6-7 Updated Pole Display installation procedures. 35 Corrected number of available Departm
91.3 Installing the Label Roll To install the label roll at any time you must follow the directions in this section. Remove the printer front-cover
10Take the new roll of labels and find the ending. Peel-off and discard about 3 labels. Place the label in the scale and thread the backing through
112. Keypad & Display2.1 Numeric KeypadThe Numeric Keypad is used to enter all numerical data in PGM Mode. In REG Mode theNumeric Keypad is used t
122.2 PLU Keypad The PLU Keypad is used to enter alpha-numerical data. To use the keypad for programming you must remove the pull-out sheet. To use
13DATETIMEMODESHIFTZEROSPACEENTERÀÜto!1)0toQPtoThis key displays the time and date in REG Mode.Used to go to PROGRAM Mode and ACC Mode.This key works
142.3. Displays 2.3.1 Weight Display The WEIGHT display shows the weight of an item on the platter whether it be positive or negative and
Front View: (with Printer Front Cover removed)LABEL PEEL SENSOR:This sensor is used in conjunction with IR LED to detect if there is alabel waiting to
163. Operation 3.1 REG mode Operations 3.1.1 Simple Weighing There are two types of sales you can generate; PLU Sales and NON-PLU Sales. PLU Sale
173.1.2 How to Use TAREKnown Tare:If you know the weight of the container you may use this method to enter the tare. For example,if the weight of the
183.1.4 Multiple Labels You can generate identical labels by using multiple label printing. To use multiple label printing, and press the X key, en
02/05/08 52,53 Corrected figures for currency setting procedures 74, 75 Added pages 74 and 75 showing label setup procedures with chart.
3.1.5 Auto Printing (AUTO MODE)In AUTO mode, labels are issued when the weight is stabilized and greater than 100g. The use ofPRT/* key will also gene
204. PROGRAM Mode4.1 System MapsTo go to PROGRAM Mode, press 1 on the numeric keypad and then the MODE key.You can press the key or the key to navigat
214.2 PLU ProgrammingPLU means Price Look Up. We store information such as the name of an item, its price, tare weight, etc.in the scale’s memory usin
22
23 1) To go to PROGRAM mode, press 1 by using numeric keys and MODE key. 2) The display shows: “PLU ”. 3) Press PRT/* key.
2410) The display shows “nAME 02.01 ”. Type in the second line of name. 11) Press PRT/* key. 12) The display shows “MSGno ”. 13) Press PRT/* key.
254.3 Preset keys Programming The preset keys are used to quickly access a PLU with only one key press. For example, if you had preset key program
26EraseMessagePRT/*PRT/*PRT/*PRT/*WithoutSavingMessageSaveMessagePRT/*If message # is “0”Input the message #(1 ~ 1000)to save the message4) The displa
271) To go to PROGRAM mode, press the number 1 key then the MODE key.2) Press key two times. The display shows “MSG”.3) Press PRT/* key. The display
281) To go to PROGRAM mode, press the number 1 key then the MODE key.6) If you wish to exit the PROGRAM mode press the C key.4.6 Programming the Shop
291) To go to PROGRAM mode, press the number 1 key then the MODE key.How to program the Shop data2) Press key four times. The display shows “SHoP”.3)
4SET #34.7 SETSET MENUDEFINITIONSDate (For details, see page 33)Time (For details, see page 34)(For details, see page 35)Department Number(For details
SET MENUDEFINITIONSSET #5SET #6SET #7SET #9SET #10(For details, see page 42)Adjust(For details, see page 44)Printing Information(For details, see page
SET MENUDEFINITIONSSET #11Currency Total Sign(For details, see page 53)1234Result Decimal Point(For details, see page 52)Decimal Point And Currency Ra
334.7.1 Programming the Date (SET #1)How to program the date1) To go to PROGRAM mode, press the number 1 key then the MODE key.2) Press key five times
344.7.2 Programming the Time (SET #2)How to program the time1) To go to PROGRAM mode, press the number 1 key then the MODE key.2) Press key five times
4.7.3 Programming the Department Number (SET #3)Ex) “98” as thedepartment #Input the SET No.(0~99)9 835How to program the department number1) Press th
4.7.4 Programming the Label (SET #4)Input the SET No.(1~99)CPRT/*460PRT/*PRT/*SET #4The label format type controls the label size and barcode format.1
0~30: Refer to Appendixfor label format31~36: Free Format0PRT/*SET #42CHow to program the label format1) To go to PROGRAM mode, press the number 1 key
PRT/*SET #44CHow to program the label mask1) To go to PROGRAM mode, press the number 1 key then the MODE key.2) Press key five times.3) The WEIGHT di
3 CONTENTS PRECAUTIONS...5 1. Installation Procedures...
PRT/*SET #44C4) Label BarcodeCPRT/*4Input the SET No.PRT/*4Enter barcode typenumber. (from charton next page)How to program the label barcode1) To go
40NoTYPE1234567891011 121314151617181234567891011121314EAN13EAN13EAN13EAN13EAN13EAN13EAN13EAN13EAN13EAN13EAN13EAN13EAN130I2of5I2of5DDI I I I ISPPPPCDD
41PRT/*SET #54C5) C LabelCPRT/*5Input the SET No.PRT/*00 = Gap Labels1 = Continuous StripHow to program the CLabel1) To go to PROGRAM mode, press the
424.7.5 Programming the Adjust Number (SET #5) - ADJUST is to adjust the position of label. - FEED is to feed label(or receipt).
43How to program the adjust number 1) To go to PROGRAM mode press 1 by using numeric keys and MODE key. 2) Press v key five times. 3) The WEIGHT d
444.7.6 Programming the Printing Information (SET #6) The printing information controls the label size, PLU item description and barcode format.
45 How to program printing information 1) To go to PROGRAM mode, press 1 by using numeric keys and MODE key. 2) Press v key five times. 3) The WEI
464.7.7 Programming the Auto Print Function (SET #7) The auto print function is used to determine when an automatic buffered label should be printe
474.7.8 Programming Baud Rate (SET #9) How to program baud rate 1) To go to PROGRAM mode, press 1 by using numeric keys a
484.7.9 SIGN (SET #10) How to enter currency/weight sign settings. You can modify scale to adjust local law (currency, weight unit, dual currency,
4.7 SET 304.7.1 Programming the Date (SET #1)4.7.2 Programming the Time (SET #2)4.7.3 Programming the Department Number (SET #3)4.7.4 Programming the
495) You can enter weight units up to 3 letters. (For example, kilogram (kg) consists of 'k' and 'g'. Enter k (107) in first lett
507) You can choose 0 (NO use) or 1 (Use unit price and printing total price's first unit sign) or 2 (Use unit price and printing total price
511) The display shows "SiGn". 2) Press 3 key and the display shows "totAL F-SiGn C1____0" 3) Type the first letter of total pr
521) Enabling currency display1) The display shows “CUrr”.2) Press the 1 key and the display shows “CUrr USinG 0”.3) Select “0” (No use) or “1” (Use C
534) Setting signs of calculated total price1) The display shows “CUrr”.2) Press the 4 key and the display shows “CUrr F-SiGn C1 0”.3) Enter the first
549) You can enter up to 3 letters for "total price last sign." For example, you want to print YTL (Turkey currency symbol) in the last pl
554) Press PRT/* key and the display shows "SEt EntEr 0". 5) Press 1 key and 2 key and PRT/* key. 1) Peel-off sensor peel-off
562) Thermal Head sensor 1) The display shows "SEt PoFF". 2) Press v key and the display shows "SEt HEAd" 3) Press
571) The display shows "SEt HEAd". 2) Press v key and the display shows "SEt PEnd" 3) Press Enter key and the display shows &qu
581) The display shows "SEt PEnd". 2) Press v key and the display shows "SEt HEAdUP" 3) Press Enter key and the display shows
5PRECAUTIONS
594.8 INIT (Initialize PLU/MSG data and Disabling ¼ and ½ keys)You can initialize PLU data, Ingredient Message data or ALL data. (both PLU and ING)You
605. ACCOUNT ModeACCOUNT Mode is used to access and clear Sales Totals, perform printhead checks andexecute Scale to Scale file transfers.5.1 System M
615.2 X Report (Read only)There are four types of X Sales Reports: Grand Total, ALL PLU’s, Non-PLU and Individual PLU’s.Each of the reports prints on
625.2.2 All PLUThere are two types of PLU Sales reports, Individual PLU’s or All PLU’s.The All PLU report will generate a total sales label for ALL ac
635.2.4 Non-PLUThe Non-PLU sales report includes the total sales information for all Non-PLU transactions.1) To go to the ACCOUNT mode, press the numb
635.2.4 Non-PLUThe Non-PLU sales report includes the total sales information for all Non-PLU transactions.1) To go to the ACCOUNT mode, press the numb
64PRT/*5.3.1 Grand Total1) To go to the ACCOUNT mode, press the number 2 key and then the MODE key.2) Press the once. The display shows “2 rPt”.$3) Pr
655.3.3 Non-PLU5.3.4 ALL1) To go to the ACCOUNT mode, press the number 2 key and then the MODE key.2) Press the once and the display shows “2 rPt”.$3)
665.4 Printhead Check (CHESS)5.5 Trans ModeThe CHESS function allows you to check the condition of the thermal print head. This testproduces several d
676. Error MessagesError 1Error 2Error 3Error 4Error 5Error 6Error 7Error 8Error 9Error 10Error 11Error 12Error 14Error 15Error 16Error 17Error 18Erro
BATTERYBATTERYAttentionMake sure to plug your scale into the proper power outlet. For maximumperformance, plug into a power outlet 30 minutes for warm
687. SpecificationsMODELLP-1000CAPACITY RESOLUTIONTAREWEIGHT DISPLAYUNIT PRICE DISPLAYTOTAL PRICE DISPLAYCONDITIONS:TEMPERATURE RANGEPOWERMEMORYCAPACI
69APPENDIX LABEL FORMAT name (Size,mm) Style Label format # #1 (2 - Iine Commodity) #2 (With Ingredient) CAS #8000 (58 x 30) #3 (1 - Iine C
70 name (Size,mm) Style Label format # #4 (2 - Iine Commodity) #5 (1 - Iine Commodity #1) Kubota #3600 (54 x 35) #6 (1- Iine Commodity #2)
71 name (Size,mm) Style Label format # #13 (2 - Iine Commodity) #14 (Whit Ingredient) #2810 (48 x 40) #15 (1 - Iine Commodity) TEC #2730 (
72 name (Size,mm) Style Label format # #24 (2 - Iine Commodity #1) #25 (1 - Iine Commodity) TEC #2834 (48 x 68) #26 (2 - Iine Commodity #2 )
73name(Size,mm)StyleLabel format#BlankLabel(58 x 60)#29 (2 - line Commodity #1)#30 (2 - line Commodity #2)name(Size,mm)Advance Label FormatSetting Met
74Setting Up the LabelThese procedures explain how to correctly set up the label in the LP-1000N. They can be used when changingfrom one label style t
75Setting Label Adjust and Feed1) Press the number 1 key followed by the MODE key. The display will show “PLU”.2) Press the key twice. The display wil
ADJUSTING LEGSRIGHT SIDELEVELING GAUGEWRONG RIGHT1. Installation Procedures1.1 CautionsA.) Environment: This scale must be installed in a dry and liqu
Feed the Pole Display connectors down through the Pole Display Bracketand up through the opening in the scale base. (See fig.)NOTE: Remove the Ferrite